A complete drawing for custom manhole steps has six element groups: dimensions and views, material specifications, load and performance requirements, code compliance references, fabrication and installation notes, and a verification checklist. Missing any one of these groups is the most common cause of fabrication rework and field fit problems. Each group is just as important as the others. A drawing with perfect dimensions but no coating thickness callout still fails at the fabricator. Readers can use this post as a section-by-section guide to check an existing drawing or build a new one from scratch. Each section explains what belongs in the group and why it matters.

Key Takeaways

  • Add measurements and views so the step spacing, width, and projection are shown clearly.

  • State the material type, grade, and coating thickness so mistakes during fabrication are avoided.

  • List the load ratings, safety factors, and slip resistance to ensure safe performance.

  • List the OSHA, ASTM, and local code references to make sure you comply.

  • Give the details for building and installing it, including tolerances and anchoring.

Dimensions and Drawing Views

Dimensions and Drawing Views

A drawing that is ready for the shop shows the manhole step assembly from three directions. The plan view places each step in relation to the manhole wall and the opening. The elevation view sets the vertical stack and the space between steps. Section views cut through the step, the wall, and the embedment to show what the surface views cannot. Every dimension on all three views has a unit, either inches or millimeters, and the drawing states the unit system once in a clear note. Mixed units lead to conversion errors at the fabricator, so the designer picks one system and uses it throughout.

Step Spacing and Alignment

Vertical spacing controls how a worker climbs up and down. The elevation view should dimension the spacing from the top of one step to the top of the next, not from centerline to centerline, because the tread surface is what the foot touches. The drawing also sets the position of the first step below the frame and the last step above the bench or invert. Alignment matters just as much. Steps should stack in a steady vertical line or a planned offset pattern, and the plan view should show that pattern clearly. One rule controls the whole assembly: all steps in one manhole must share the same design type and size. Mixing unmatched steps is not allowed. A drawing that calls for one step type at the top and a different type lower down creates two shop setups, two inspection routines, and a field crew that must sort parts before installation. The designer should also avoid loose steps in the design. A loose step has no solid attachment to the structure, so it can shift, rotate, or pull free under load. The drawing should show every step firmly anchored, with the anchor or embedment detailed in the section view.

Width, Projection, and Tread Depth

Three dimensions define the usable climbing surface. Width is the clear horizontal span of the tread. Projection is how far the step extends from the wall face. Tread depth is the dimension the foot rests on, measured front to back. The plan view should carry the width and projection, and the section view should carry the tread depth and the wall-to-step relationship. These dimensions affect each other. A large projection with a shallow tread depth gives the foot little to stand on. A deep tread with a short projection crowds the climbing space. The designer should dimension all three on the same drawing so the fabricator and the installer see the full geometry. The section view should also show the step's angle to the wall, since a tilted tread changes the effective standing surface. Finally, the drawing should dimension the projection from a fixed reference, such as the finished wall face, rather than from an approximate surface. Precast and cast-in-place walls finish at different planes, and a projection tied to the wrong reference will not match the field condition.

Material Specifications for Custom Manhole Steps

Material Type, Grade, and Coating

The material block tells the fabricator exactly what to buy and how to finish it. Designers of custom manhole steps usually pick from three families, and each one fits a different set of project conditions. Cast iron is still a standard material, and it works for projects that follow long-established city specs and expect a heavy, rigid step. Steel-reinforced copolymer polypropylene in a super high impact grade fits structures where light weight, electrical non-conductivity, and resistance to road salt matter most. Composite and SMC options fit projects that want molded shapes, steady pricing, and a non-metallic finish. No single family is best everywhere. The drawing should name the family, the grade, and the reinforcement or molding process so the shop cannot swap in a lower grade.

The coating callout needs its own line on the drawing. The designer states the coating type, such as a hot-dip metallic finish or a molded polymer surface, and the required thickness. A bare material name leaves the finish open to interpretation, and two fabricators will deliver two different products under the same drawing number.

Corrosion Resistance Requirements

Manhole environments expose steps to moisture, salts, and chemical attack from the surrounding soil and runoff. The drawing should state the corrosion performance the step must deliver over its service life. A performance statement works better than a vague instruction to "protect against rust." The designer can reference the coating system, the base material's own resistance, or both. The requirement should match the exposure. A step in a coastal or deicing-salt area needs a stronger statement than one in a dry inland site. The drawing should also note any galvanic pairing concerns where a metal step meets a metal frame. Dissimilar metals in contact can speed up corrosion at the joint. A short note on isolation or compatible materials prevents a field problem that no dimension can fix.

Load and Performance Requirements

Load Ratings and Safety Factors

A manhole step holds a person, their gear, and the moving force of climbing. The drawing should state the design load the step must handle and the safety factor used on that load. The designer gives the load as one vertical force at the tread, plus any sideways force from a worker pulling on the step. The safety factor multiplies the design load to cover material differences, installation mistakes, and wear over time. A drawing that lists only a design load leaves the fabricator guessing at the margin.

The load statement should also name the test method or the basis for the rating. A rating with no test basis is an opinion, not a specification. The designer can cite a recognized structural test or a manufacturer's published rating for the step type specified. The drawing should tie the rating to the exact step type and size named in the material block. A rating copied from a different product line does not carry over to the custom step.

Slip Resistance and Durability

The tread surface must grip a wet boot. The drawing should state the slip resistance the tread must provide and the condition under which the shop checks it. A textured, serrated, or molded pattern on the tread gives the foot an edge to catch. The designer should show that pattern in the plan view and note its depth in the section view. A smooth tread that meets every dimensional callout still fails the worker on a damp day.

Durability ties back to the material and coating choices. The drawing should state how the step resists wear at the tread, corrosion at the embedment, and fatigue at the anchor. The designer can require a coating or surface treatment that keeps its grip after repeated use. The performance statement should match the service environment, since a step in a wet well sees different wear than one in a dry utility vault. A clear durability requirement gives the fabricator a target and gives the inspector a basis for acceptance.

Code Compliance Details

OSHA and ASTM References

The drawing needs to list the safety and testing standards the step has to meet. OSHA makes rules for fixed ladders and climbing devices in general industry workplaces. Its rules cover step spacing, the least load the step can hold, and how far the step sits from the wall. ASTM puts out test methods for manhole step performance, such as load testing and slip resistance checks. The designer names these standards and their editions on the drawing, so the fabricator and the inspector both work from the same benchmark.

Just citing a standard does not make a drawing compliant. The designer should link each reference to a specific requirement in the drawing, like the load rating or the spacing dimension. A note that says "steps shall conform to OSHA and ASTM" gives the shop no target it can measure. A note that names the standard, the clause, and the value the step must meet gives everyone a clear basis for acceptance.

Local Codes and Manufacturer Callouts

City and utility specs often add requirements on top of the national standards. Some cities publish their own list of approved steps, and others set spacing or material rules that differ from the model codes. The designer should check with the local jurisdiction before release and note any local amendment on the drawing. A step that meets OSHA but misses a city requirement still fails inspection.

The drawing should also name manhole step manufacturers that are acceptable. Examples include MA Industries, Inc. (Type PS-2-B) and American Step Company, Inc. Naming approved products removes confusion at bid time and stops substitutions that do not match the specified geometry. The contract drawings should show the specified design type and size, so the contractor orders the exact product the designer intended. A clear manufacturer callout, paired with the design type and size, closes the gap between the specification and the step that gets delivered.

Fabrication and Installation Notes

Tolerances and Welding Details

The drawing should list the building tolerances the shop has to meet. Step spacing, projection, and tread alignment all need an allowed range of variation. If a drawing has no tolerance note, each fabricator picks its own standard, and two shops will make two different fits. The designer should also set tolerances for where the anchor sits and the step's angle to the wall. These values connect straight to the field fit, so the shop needs them before it cuts any material.

Welding details belong on the drawing any time the step design uses welded joints. The designer should show the weld type, where the joint goes, and the finish needed after welding. A welded joint in a wet place needs a coating repair note, because the weld burns off the original finish. The drawing should also name the welding procedure or point to a recognized standard, so the shop uses the same process on every unit.

Anchoring and Embedment Requirements

The embedment detail changes with the type of structure. Precast manholes form the step anchors into the wall at the plant, so the drawing must show where the anchor sits compared to the form and how deep it must be embedded. Cast-in-place structures set the anchors in the field, so the drawing must show the anchor layout, the embedment depth, and how to hold the anchor in place while the concrete is poured. One generic note cannot cover both cases.

Structure Type

Anchor Setting

Drawing Must Show

Precast

Set in the form at the plant

Anchor position to the form, embedment depth

Cast-in-place

Set in the field during the pour

Anchor layout, embedment depth, hold-down method

The drawing should also state the smallest embedment depth for each anchor type and the pull-out strength the anchor must deliver. A step that meets every dimension callout can still fail if the anchor sits too shallow in the concrete.

Custom Manhole Steps Drawing Checklist

Custom Manhole Steps Drawing Checklist

Pre-Submittal Verification Items

A designer can do one last check before the drawing leaves the office. The six element groups in this guide make up a single checklist. Each item gets a check mark or a fix. A drawing that passes all six items is ready for the fabricator.

Group

Verification Item

Pass Criteria

Dimensions and views

Plan, elevation, and section views present

Every dimension has a unit; one unit system is stated

Material specifications

Material family, grade, and coating named

Coating type and thickness are called out on their own line

Load and performance

Design load, safety factor, and test basis stated

Rating is tied to the exact step type and size

Code compliance

OSHA and ASTM references listed with editions

Local amendments are noted; approved manufacturers are named

Fabrication and installation

Tolerances, welding details, and embedment shown

Precast and cast-in-place cases are each detailed

Verification

Drawing checked against this list

No open items remain

The designer should go through the list in order. Dimensions come first because every later group depends on the geometry. Material and load come next, since the coating and the rating attach to the named step type. Code references and fabrication notes finish the pass. A drawing that fails an early item usually fails a later one too.

Common Omissions to Catch Before Release

Four omissions cause most of the rework on custom manhole steps drawings. Each one is easy to catch with a focused check.

The first is a missing view. A drawing with a plan view and an elevation view but no section view leaves the embedment and the tread depth undefined. The shop cannot build what it cannot see. The designer should confirm all three views before release.

The second is unmatched step types within one manhole. A drawing that specifies one type at the top and another lower down breaks the same-type rule. The fix is simple. The designer picks one design type and one size, then applies it to every step in the structure.

The third is an unspecified coating thickness. A material name alone does not define the finish. Two shops will deliver two different products under the same drawing number. The coating type and thickness belong on their own line.

The fourth is a missing manufacturer callout. Without an approved manufacturer, the contractor may substitute a product that does not match the specified geometry. Naming acceptable manufacturers, such as MA Industries, Inc. (Type PS-2-B) and American Step Company, Inc., closes that gap. The contract drawings should also show the specified design type and size.

A short review against these four items takes little time. It prevents the rework, the field fit problems, and the approval delays that follow an incomplete drawing.

A drawing that is ready for the shop includes all six element groups: dimensions and views, material specifications, load and performance requirements, code compliance references, fabrication and installation notes, and a verification checklist. Each group matters just as much as the others. If a designer leaves out one group, the fabricator gets an incomplete package.

Designers should check every custom manhole steps drawing against the checklist before release. The review takes only a little time. It catches missing views, unmatched step types, thin coating callouts, and missing manufacturer names. A complete drawing reduces rework, speeds up approval, and helps ensure a safe installation that meets code. The checklist turns a good intention into a finished document that can be built.

FAQ

What makes a manhole step drawing complete?

A complete drawing covers six element groups: dimensions and views, material specifications, load and performance requirements, code compliance references, fabrication and installation notes, and a verification checklist. Each group counts the same. If a drawing skips any one group, it will likely come back from the fabricator with questions or rework.

Can a designer mix step types within one manhole?

No. Every step in a single manhole must have the same design type and size. Mixing unmatched steps makes the shop set up twice and run two inspection routines. The field crew then has to sort parts before installation. The drawing should name one type and one size for the whole structure.

Why does coating thickness need its own line on the drawing?

A bare material name does not define the finish. Two fabricators will deliver two different products under the same drawing number. The coating type and thickness belong on a separate line, so every shop bids and builds to the same target.

How does embedment differ between precast and cast-in-place structures?

Precast manholes set the anchors in the form at the plant. The drawing must show where the anchor sits compared to the form and how deep it goes. Cast-in-place structures set anchors in the field during the pour. That case needs the anchor layout, the embedment depth, and a hold-down method.

What should a designer check before releasing a custom manhole steps drawing?

Run the drawing against the six-group checklist. Make sure all three views are there, step types match throughout, coating thickness is called out, and approved manufacturers are named. A short review catches the four omissions that cause most rework on custom manhole steps.

Elite New Materials is a leading provider of advanced SMC (Sheet Molding Compound) products, backed by over 20 years of dedicated experience in the building materials industry.